field measuring instruments i i i i n n n n s s s s u u u u l l l l a a a a t t t t i i i i o o o o n n n n t t t t e e e e s s s s t t t t i i i i n n n n g g g g - - - - t t t t h h h h e e e e n n n n e e e e x x x x t t t t g g g g e e e e n n n n e e e e r r r r a a a a t t t t i i i i o o o o n n n n hioki company overview, new products, environmental considerations and other information are available on our website. http://www.hioki.co.jp/ 3 3 3 3 4 4 4 4 5 5 5 5 4 4 4 4 - - - - 5 5 5 5 1 1 1 1 3 3 3 3 4 4 4 4 5 5 5 5 4 4 4 4 - - - - 1 1 1 1 0 0 0 0 no ce marking digital m ? hitester 3454 -11, -51 (3-range) 3454 -10 (4-range)
9288 breaker pin to be attached on top of 9294 (red) 9294 test probe lead length approx. 1.2 m (47.2") 90mm (3.54" ) *1. measurement range shifts automatically. ? 3454 series specifications accuracy at 23?c 5?c (73?f 9?f), 90 % rh or less 3454 -11, 3454 -10 digital m ? hitester (includes 9294 test probe and strap band) *3454 -51 digital m ? hitester (includes *9289 test probe , *alligator clips and strap band) * *no ce marking options accessories other functions: insulation and low resistance mode - comparator, measurement value hold; insulation resistance mode - auto discharge ; insulation and ac voltage mode - live wire warning (when voltage of 70v 10v exists across measurement terminals); low resistance mode - zero adjust; all measurement modes - battery indicators, auto power save display: semi-transparent lcd, "4000" count display update rate: 2 times / second load protection( 10 s) : insulation resistance mode - 600 vrms (1000 v range; 1200 vrms); ac voltage mode - 800 vrms ; low resistance / continuity mode - 600 vrms (fuse protection) safety standard: en61010-1 cat iii 600 v emc standard: en61326 ambient temperature range for use: 0 to 40?c (32?f to 104?f) , 90% rh or less (no condensation) ambient temperature range for storage: -20 to 50?c ( - 4?f to 122?f) , 90% rh or less (no condensation) power source: r6p manganese battery ? 4 or lr6 alkaline battery ? 4 dimensions and mass: approx. 175 (6.9") w ? 148 (5.9") h ? 56 (2.3" ) d mm; approx. 530 g (18.7 oz. ) (with display cover closed) insulation test voltage 250 v dc measurement range* 1 4.000 / 40.00 / 400.0 / 500 / 4000 (1000 v range only) m ? 1st effective range 0.200 to 50.0 m ? insulation 2nd effective range 0 to 0.199 / 50.1 to 500 m ? resistance accuracy 1st effective range: 3 %rdg. 4 dgt. / 2nd effective range: 5 %rdg. 5 dgt. voltage with no load not more than 1.2 ? rated measurement voltage short circuit current 1.2 ma max. response time to center, to 0 m ? within 5 s (within accuracy range) low resistance (continuity) measurement range: 40.00 / 400.0 / 4.000 k / 40.00 k / 400.0 k / 4.000 m ? short circuit current: 200 ma accuracy: 3 %rdg. 6dgt. ( 5 %rdg. 6dgt. at 400 k ? range or higher) , open terminal voltage: 4 to 6 v, response time: 5 s max. ac voltage display indication range : 0 to 750 v, accuracy: 3 %rdg. 6 dgt. (up to 600v) , frequency range: 50 / 60 hz, input impedance: 100 k ? 3454se3-3xb-05k printed in japan all information correct as of oct. 3, 2003. all specifications are subject to change without notice. head office : 81 koizumi, ueda, nagano, 386-1192, japan tel +81-268-28-0562 / fax +81-268-28-0568 e-mail: os-com@ hioki.co.jp hioki usa corporation : 6 corporate drive, cranbury, nj 08512 usa tel +1-609-409-9109 / fax +1-609-409-9108 e-mail: hioki@ hiokiusa.com distributed by function reference value (3454-11 & 3454-51) 0.2/0.4/0.5/1/2/3/5/10/20/30/50/100/200 (m ? ) 1/2/3/5/10/20/30/50/100/200/500/1000/2000 (m ? ) continuity 0.5/1/2/3/4/5/6/10/20/30/50/100/200/1k ( ? ) 250 v/500 v 1000 v insu- lation compact storage without disconnecting test probes back-lighting liquid crystal display for easy reading in dark areas. buzzer on fail at 20 m ? or less buzzer can be set to sound on either pass or fail buzzer on pass at 10 ? or less insulation ? : meas. value < ref. value ? fail , ref. value < meas. value ? pass continuity: meas. value < ref. value ? pass , ref. value < meas. value ? fail ex. insulation resistance ex. continuity 9257 connection cord lead length approx. 1.3 m (51.1") insulation measurement through sight and sound! the reference value is set separately for each measurement range. checks ground wire continuity with a short current of 200 ma also capable of testing the continuity of electrical facility grounds in accordance with iec 60364. 500 v dc 250 v dc 125 v dc 50 v dc 1000 v dc 500 v dc mo del 3454 -11 & 3454 -51 3454 -10 4.000 / 40.00 / 200.0 m ? 4.000 / 40.00 / 400.0 / 2000 m ? 0.200 to 10.00 m ? 0.200 to 200.0 m ? 0.200 to 100.0 m ? 0 to 0.199 / 200.1 to 4000 m ? 0 to 0.199 / 10.01 to 200.0 m ? 0 to 0.199 / 100.1 to 2000 m ? *no ce marking for 3454 -11 , -10 9289 test probe lead length approx. 1.2 m (47.2") for 3454 -51 with attachable alligator clips * shanghai representative office : 1704 shanghai times square office 93 huaihai zhong road shanghai, 200021, p.r.china tel +86-21-6391-0090, 0092 fax +86-21-6391-0360 e-mail: info@hioki.cn
|