  field measuring instruments i i i i n n n n s s s s u u u u l l l l a a a a t t t t i i i i o o o o n n n n t t t t e e e e s s s s t t t t i i i i n n n n g g g g - - - - t t t t h h h h e e e e n n n n e e e e x x x x t t t t g g g g e e e e n n n n e e e e r r r r a a a a t t t t i i i i o o o o n n n n hioki company overview, new products, environmental considerations and other information are available on our website. http://www.hioki.co.jp/ 3 3 3 3 4 4 4 4 5 5 5 5 4 4 4 4 - - - - 5 5 5 5 1 1 1 1 3 3 3 3 4 4 4 4 5 5 5 5 4 4 4 4 - - - - 1 1 1 1 0 0 0 0 no ce marking digital m ? hitester 3454 -11, -51 (3-range) 3454 -10 (4-range)
9288 breaker pin to be attached on top of 9294 (red) 9294 test probe lead length approx. 1.2 m (47.2") 90mm (3.54" ) *1. measurement range shifts automatically. ? 3454 series specifications accuracy at 23?c5?c (73?f9?f), 90 % rh or less 3454 -11, 3454 -10 digital m ? hitester (includes 9294 test probe and strap band) *3454 -51 digital m ? hitester (includes *9289 test probe , *alligator clips and strap band) * *no ce marking options accessories other functions: insulation and low resistance mode - comparator, measurement value hold; insulation resistance mode - auto discharge ; insulation and ac voltage mode - live wire warning (when voltage of 70v 10v exists across measurement terminals); low resistance mode - zero adjust; all measurement modes - battery indicators, auto power save display: semi-transparent lcd, "4000" count display update rate: 2 times / second load protection( 10 s) : insulation resistance mode - 600 vrms (1000 v range; 1200 vrms); ac voltage mode - 800 vrms ; low resistance / continuity mode - 600 vrms (fuse protection) safety standard: en61010-1 cat iii 600 v emc standard: en61326 ambient temperature range for use: 0 to 40?c (32?f to 104?f) , 90% rh or less (no condensation) ambient temperature range for storage: -20 to 50?c ( - 4?f to 122?f) , 90% rh or less (no condensation) power source: r6p manganese battery ? 4 or lr6 alkaline battery ? 4 dimensions and mass: approx. 175 (6.9") w ? 148 (5.9") h ? 56 (2.3" ) d mm; approx. 530 g (18.7 oz. ) (with display cover closed) insulation test voltage 250 v dc measurement range* 1 4.000 / 40.00 / 400.0 / 500 / 4000 (1000 v range only) m ? 1st effective range 0.200 to 50.0 m ? insulation 2nd effective range 0 to 0.199 / 50.1 to 500 m ? resistance accuracy 1st effective range: 3 %rdg. 4 dgt. / 2nd effective range: 5 %rdg. 5 dgt. voltage with no load not more than 1.2 ? rated measurement voltage short circuit current 1.2 ma max. response time to center, to 0 m ? within 5 s (within accuracy range) low resistance (continuity) measurement range: 40.00 / 400.0 / 4.000 k / 40.00 k / 400.0 k / 4.000 m ? short circuit current: 200 ma accuracy: 3 %rdg. 6dgt. (5 %rdg. 6dgt. at 400 k ? range or higher) , open terminal voltage: 4 to 6 v, response time: 5 s max. ac voltage display indication range : 0 to 750 v, accuracy: 3 %rdg. 6 dgt. (up to 600v) , frequency range: 50 / 60 hz, input impedance: 100 k ? 3454se3-3xb-05k printed in japan all information correct as of oct. 3, 2003. all specifications are subject to change without notice. head office : 81 koizumi, ueda, nagano, 386-1192, japan tel +81-268-28-0562 / fax +81-268-28-0568 e-mail: os-com@ hioki.co.jp hioki usa corporation : 6 corporate drive, cranbury, nj 08512 usa tel +1-609-409-9109 / fax +1-609-409-9108 e-mail: hioki@ hiokiusa.com distributed by function reference value (3454-11 & 3454-51) 0.2/0.4/0.5/1/2/3/5/10/20/30/50/100/200 (m ? ) 1/2/3/5/10/20/30/50/100/200/500/1000/2000 (m ? ) continuity 0.5/1/2/3/4/5/6/10/20/30/50/100/200/1k ( ? ) 250 v/500 v 1000 v insu- lation compact storage without disconnecting test probes back-lighting liquid crystal display for easy reading in dark areas. buzzer on fail at 20 m ? or less buzzer can be set to sound on either pass or fail buzzer on pass at 10 ? or less insulation ? : meas. value < ref. value ? fail , ref. value < meas. value ? pass continuity: meas. value < ref. value ? pass , ref. value < meas. value ? fail ex. insulation resistance ex. continuity 9257 connection cord lead length approx. 1.3 m (51.1") insulation measurement through sight and sound! the reference value is set separately for each measurement range. checks ground wire continuity with a short current of 200 ma also capable of testing the continuity of electrical facility grounds in accordance with iec 60364. 500 v dc 250 v dc 125 v dc 50 v dc 1000 v dc 500 v dc mo del 3454 -11 & 3454 -51 3454 -10 4.000 / 40.00 / 200.0 m ? 4.000 / 40.00 / 400.0 / 2000 m ? 0.200 to 10.00 m ? 0.200 to 200.0 m ? 0.200 to 100.0 m ? 0 to 0.199 / 200.1 to 4000 m ? 0 to 0.199 / 10.01 to 200.0 m ? 0 to 0.199 / 100.1 to 2000 m ? *no ce marking for 3454 -11 , -10 9289 test probe lead length approx. 1.2 m (47.2") for 3454 -51 with attachable alligator clips * shanghai representative office : 1704 shanghai times square office 93 huaihai zhong road shanghai, 200021, p.r.china tel +86-21-6391-0090, 0092 fax +86-21-6391-0360 e-mail: info@hioki.cn


▲Up To Search▲   

 
Price & Availability of 3454-10

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X